Online PD Monitoring 16 Channel Multiplexer
Home >> Technical >> Online PD Monitoring 16 Channel Multiplexer

Multiplexer
The unitis designed to be used in conjunction with the
Digital PD instruments Types HVS1000-2000 PDD/T The
multiplexer is operated from the Digital PD unit using the
PD gold software supplied . In this way up to 16 channels of
data can be monitored using the Digital PD instruments
The unit is designed to monitor 16 channels of partial
discharge activity of high voltage insulation on 50/60Hz
power systems.
The unit is connected to the Digital PD unit via a USB link
which selects the required channels. PD signals are then
directed from one of the 16 channels to the digital
discharge detector.
PD Gold Monitor Software
The PD Gold monitor software gives control over the monitor , displays the real- time data and allows the
historical data to be displayed and analysed. Please ask for leaflet HVS PDG1 2000-02-09 which gives
further details
M&B Systems also manufacture a range of Specialised test equipment for both
on-line and off-line testing of electrical plant . For further information on these products
please contact our sales office
PD GOLD monitor software for use with Digital Partial Discharge detectors -
Type HVS 1000-2000 PDD/T
The PD GOLD monitor software is the heart of the monitoring system. It gives control over the monitor and
multiplexer, displays the real-time data and allows the historical data to be displayed and analysed.
Main Monitor window

This window allows control of the
monitoring tasks. In addition the software
takes care of real-time display of the
current channel and data, a resume of the
historical data for each connected channel
and a display of all the monitoring
parameters. PD calibration is included as
standard in this software.
The main features of the software are as follows:-
- Control of digital discharge detector and 16 channel multiplexer during monitoring process
- Real time display of the current data, and historical data for each connected channel
- Storage of user supplied data for location, channels, staff etc
- Calibration facilities to allow measurements in pC (pico Coulombs)
- Indicators of the current state of the digital discharge detector, and multiplexer
- User settable monitoring time
- Data storage file for full monitor data, and separate file for small ‘summary’ data file. This can be used to
access status remotely without the need for transfer of large data files.
- Data analysis and display window to view all 16 channels of data simultaneously
Monitor Analysis window

All the data from all the channels can be
viewed separately or together as required.
Peak values, average values, number of pulses
above threshold, and many other PD
parameters can be displayed using this
analysis window. |